Definition of a Bedroom

Within today’s custom homes it is not uncommon to see exercise rooms, sewing rooms,

studies, offices, dens, family rooms and other similarly labeled non-bedroom spaces

shown on residential house plans. However, these same rooms can and are used as

bedrooms when a family grows or the house is sold to another family which has different

needs. To make sure the home is served by a sewage disposal system which is sized

properly, the system must be based on the potential number of bedrooms in the house.

There are certain standards by which a room can be deemed a potential bedroom. They

provide:

1. A defined habitable space per Building Code requirements. The exception to this

statement would pertain to obvious future habitable space (such as an unfinished

second floor in a “cape” style home) which has the appropriate structural shell but

has not been “finished” to meet Building Code standards for habitable space.

2. Privacy to the occupants.

3. Full bathroom facilities (containing either a bathtub or shower) which are

conveniently located to the bedroom served.

4. Entry from a common area, not through a room already deemed a bedroom.

Consideration should be given to the number of rooms in a new dwelling which may be

used as bedrooms, even though the builder may not intend to use them as such. This is

particularly true for homes built on speculation, since the builder has no control over who

purchases the dwelling. Generally, all rooms on the second floor of a two story house,

except for the bathroom and hallway, are considered bedrooms. Two bedroom houses are

allowed by the Public Health Code. However, such buildings would be expected to be

relatively small in total floor area. Any new dwelling containing over six rooms or 1500

square feet normally should be served by a sewage disposal system suitable for a three

bedroom house.

A significant number of homes are being constructed with habitable space above a two or

three car garage. This space may be accessible form either the first or second floors or

both. They are typically labeled as second floor playrooms or bonus rooms, may be quite

large in area and have the potential to be a bedroom. Using the above criteria, this space

should be deemed a bedroom when access is from the second floor and a full bathroom is

readily available. The same designation would apply if access were provided from both

the second and first floor. It would not be designated a bedroom if the only way to gain

access to this second floor room were perhaps from a first floor stairway when the first

floor does not have a full bathroom facility access is from the garage.

Residential - Walk In - BEDROOM ADDITIONS

a. All permit applications must be made in person.

b. Foundation may be of engineered design or comply with Figure R403.1.1 in the

2003 IRC

c. Addition must comply with the light, ventilation and heating requirements of sec.

R303 of the 2003 IRC.

d. The minimum ceiling height for a habitable room is 7 feet.

e. The minimum habitable room area is 70 sq. ft.

f. Habitable rooms shall not be less than 7’ in any horizontal dimension. Portions of

a room with a sloping ceiling measuring less than 5 feet or a furred ceiling

measuring less than 7 feet from the finished floor to the finished ceiling shall not

be considered as contributing to the minimum required habitable area for that

room.

g. At least one emergency escape and rescue opening is required.

h. Openings from the garage directly into a room used for sleeping purposes shall

not be permitted.

i. Water heaters located in a bedroom or bathroom shall be installed in a sealed

enclosure so that combustion air will not be taken from the living space. Access

to such enclosure may be from the bedroom or bathroom when through a solid

door, weather-stripped in accordance with the exterior door air leakage

requirements of the International Energy Conservation Code and equipped with

an approved self-closing device. Direct-vent water heaters are not required to be

installed within an enclosure.

j. Smoke alarms are required in each sleeping room and outside each sleeping area

in the immediate vicinity of the bedroom. New smoke alarms shall be

interconnected with existing smoke alarms and primary power shall come from

the building wiring with battery backup.

k. Natural light and ventilation requirements for existing rooms cannot be reduced

below minimum code requirements.

l. Existing required bedroom emergency escape and rescue windows must be

maintained or replaced.

m. Addition must demonstrate compliance with the requirements of the Energy Code

of the City of Fort Worth for the addition.

n. Room additions with open spans in excess of 24 feet require engineered design.